Description
ACS01E Click to download the document
catalogue
1.3 1.3 Overview of the Door Lock Plate Function 4 4
3.2 3.2 Typical Applications 7 7
3.2.1 3.2.1 Directly Controlled Electric Lock 7 7
3.2.2 3.2.2 Control the elevator entrance button 9 9
1. Product Overview
1.1 summary
The ACS01E is a Bluetooth access-control controller specifically developed for use in apartments, hotels, and guesthouses. It allows electric door locks, magnetic locks, and similar devices to be controlled directly using cards, passwords, or mobile-phone-based authorization issued through networked lock management software (or an app). This makes it easier for operating venues to enhance access-security management.
1.2 Product image

1.3 Introduction to the Door Lock Plate Function
As shown in Table 1.1, this section introduces the functional characteristics of the ACS01E.
Table 1.1 Characteristics of the ACS01E door lock plate
| function | parameter |
| Key Type | Password + card + app (Bluetooth is standard; other features are optional based on needs) |
| Number of keys | 889 pieces
Total number of shared keys issued via cards/passwords (including issued passwords and offline passwords); offline card issuance is not included in this count. |
| current consumption | 120mA |
| environment | temperature:-10~65℃
Storage temperature: -25 to 125 °C Humidity: 20%–93% |
| power suppl | 12VDC |
| Wireless standards | ( BLE4.2 ( 433MHz ( BLE4.2 ( 433MHz |
| import | (Door-opening button signal (password input) |
| output | (Dry contact node group 1 (NO/NC/COM)) |
| self checking function | (Power-on self-test (Operational self-test (Watchdog) |
| Timeliness management | (Freeze, enable, and delete all keys/user keys or individual keys)
(The time-limited password card has been issued; the time-limited fingerprint has been added.) (Offline time-sensitive password) (A one-time password valid for half an hour) (Time-sensitive WeChat Mini Program features |
| Status detection | (Inclined tongue (reverse locking (battery level) (Inclined tongue (reverse locking (battery level) (Inclined tongue (reverse locking (battery level) |
| Alarm function | (Low battery level alarm (Test opening alarm (Lock-picking alarm) |
| safety function | (Anti-peeping password protection (Anti-replay attack protection (Random secret key allocation for door locks |
| Software support | ( Wishome/ldlock ( wisapartment/LDRenting |
| Open Platform | ( LDIOT |
2. Initial access control status

In the initial state, the project installation can be unlocked by pressing “123456#”.

In the initial state, turning on the screen will automatically enter the “ready to add” state, with the number 5 LED flashing. After installation using the installation card (or the app), the device can exit the initialization state.
Note: The installation method varies, and the scenarios for which it is suitable also differ.
- If the system is used in residential apartments or similar settings and is managed through a decentralized approach, please use the Huixiangjia or Huixiang Apartment app to install the door locks. The installation procedure is the same as that for the connected locks used in apartments.
- If the system is to be used in a setting with centralized management, such as a hotel, please have the networked lock management system provider produce an access-control installation card before completing the installation.
3. Detailed Feature Description
3.1 hookup

As shown, this is the wiring diagram for the Bluetooth access control controller; each wire sequence is described in Table 3.1.
Table 3.1 Wiring Instructions
| name | pigment | explain |
| +12V | red | The positive input port of the controller’s power supply accepts a DC voltage of 9–12 V. |
| GND | black | Common ground of the controller |
| undefinition | Citrus sinensis | |
| undefinition | Lan | |
| SW | Green | Door-opening button input signal |
| NO | Huang | A normally open output port is provided for connecting power-off unlocking electric locks or other devices. |
| NC | Gray | A normally closed output port, used to connect power-activated unlocking electric locks or other devices. |
| COM | white | On the common terminal, the positive terminal of the power supply can be connected to provide power to the electric lock. |
3.2 Typical Applications
3.2.1 Direct-control electric lock

Figure 3.1 Wiring diagram for the directly controlled electric lock of the ACS01E
The ACS01E access control controller can control various types of electric locks, including electric plug locks, electromagnetic locks, and electronically controlled locks. These electric locks can be divided into two types: those that unlock when powered on and those that unlock when power is cut off. In the former type, once powered on, the lock opens (for example, the latch of an electric plug lock retracts); when power is cut off, it automatically relocks (for example, the latch extends). The latter type behaves in the opposite manner. To comply with fire safety requirements, power-off unlocking locks are generally used. The connection methods between these two types of locks and the controller differ slightly, as shown in Figure 3.1 above.
For a power-off unlocking electric lock, connect the positive terminal of the power supply to the normally closed (“NC”) terminal of the controller and the negative terminal to the “GND” terminal. Under normal conditions, the “NC” terminal provides a 12 V output voltage (assuming that the power supply voltage connected to the controller is 12 V), keeping the electric lock in the locked state. When the card is read and the door opens, power is disconnected from the “NC” terminal, causing the electric lock to enter the unlocked state.
For power-on unlocking electric locks, the positive terminal of the power supply is connected to the normally open (“NO”) terminal of the controller, and the negative terminal is connected to the “GND” terminal. Under normal conditions, no voltage is output from the “NO” terminal, so the electric lock remains in the locked state. When the card is swiped to open the door, the “NO” terminal outputs 12 V of voltage, causing the electric lock to switch to the unlocked state.
pay attention to:
- Once a valid door-lock card is read, the electric lock will open for 5 seconds and then close automatically.
- The electric lock can also be controlled using the door-opening button; it accepts dry-contact or TTL-level inputs.
- The operating current of an electric lock is relatively high, typically around 0.5 A. Therefore, the wire gauge used for the connection between the electric lock and the controller should be at least 0.5 mm²; do not use Ethernet cables.
3.2.2 Control the elevator entrance button

Figure 3.2 Wiring diagram for the ACS01E direct elevator entrance button
As shown in Figure 3.2, there are generally two buttons at the elevator entrance. Each button has two connecting wires, bringing the total to four wires. Two of these wires should be identical; cut them off and connect them separately to the NC and COM wires of the access control controller.
4. Audible and visual alert for the door lock
The audible and visual alerts for the door lock are shown in Table 4.1.
Table 4.1 Auditory and Visual Indications of Door Locks
| function | Voice prompt for the door lock | |
|
Functional Status Indicator Class |
||
|
Routine functional indicators
|
Lock opening | Do-Re-Mi |
| Operation successful | A long, sustained tone | |
| Locking mechanism | Automatic locking: silent mode | |
| Manual lock release: Mi-la-duo | ||
| initialise | Press and hold: a short beep every second à hold for at least 8 seconds → two short beeps, indicating that you can release the button → release the button; initialization succeeds, followed by one long beep. | |
| After two short beeps, the number 5 flashes red at a frequency of 1 Hz for 5 cycles until success is achieved.
Restore all LEDs to the illuminated state; the red indicator for the digit “5” should disappear. |
||
| Initial state | “Beep~ beep~ beep~” — three long beeps signal the start of the pairing process. | |
| During the pairing process, the white light and the red light corresponding to position No.5 flash alternately. | ||
| Press the button | Toggle the full-screen display on and off once. | |
| The buzzer emitted a short “beep~” sound. | ||
| Add a key | The full-screen display remains illuminated for 30 seconds. | |
| The buzzer emits two short beeps: “beep~ beep~” | ||
| Operation failed | Three short clicks | |
| The full-screen display flashes on and off three times (the number 5 flashes red light three times). | ||
| Synchronizing data | Digital display: 5; blue light flashes once every 1 second. | |
| Firmware upgrade in progress | Digital display: 5; blue light flashes once every 1 second. | |
|
Alert type |
||
| Functional alarm notification | Trial-and-error alert | Password/card/fingerprint authentication uses a trial-and-error approach: each incorrect attempt triggers an audio-visual “operation failed” alert. After five failed attempts, a siren sounds, and the system locks for one minute; no input is accepted during this period, with a brief beep sounding every 10 seconds. |
| Each time a drop is applied, the number 5 flashes red once. | ||
| Alarm: The key list is full. | Same as “Operation Failed” | |











Reviews
There are no reviews yet.