Description
EVC01E-MB40W0-16-ZD Installation manual, click to download
catalogue
1.3 1.3 Functional Features 4 4
2.1 2.1 Understanding the Wiring Sequence of Elevator Buttons 6 6
2.2 2.2 Description of Operating Modes 6 6
2.3 2.3 Overall Wiring Diagram 7 7
2.4 2.4 Wiring of the elevator control buttons 7 7
1. Product Overview
1.1 summary
The EVC01E-MB40W0-16-ZD is an intelligent elevator floor controller that supports control via cards and Bluetooth. The single board provides 16 output interfaces (up to four boards can be cascaded, enabling control of up to 64 floors), and it supports flexible configuration of normally open/normally closed signals. The product employs an advanced integrated design and represents a new generation of elevator access-control equipment, offering advantages such as stable performance, efficient communication, high capacity, and strong compatibility.
1.2 Product image

1.3 functional characteristics
- Supports two authentication methods for elevator access: card-based authentication and Bluetooth authentication.
- The time-based access control feature is supported; users whose access period has expired cannot use the service.
- It supports Bluetooth Quick Connect functionality, enabling contactless elevator access using a smartphone.
- Supports OTA firmware updates.
1.4 function Introduction
As shown in Table 1.1, this section provides an overview of the functions of the EVC01E-MB40W0-16-ZD elevator floor controller.
Table 1.1: Specifications of the EVC01E-MB40W0-16-ZD Elevator Floor Controller
| function | parameter |
| type of use | Mifare card (MEVC) & Bluetooth |
| Card reading distance | 10~50mm |
| import | not have |
| output | 16 normally closed contacts; in direct-mode operation, there are an additional 16 normally open contacts. |
| power suppl | 12V DC |
| current consumption | 1000mA |
| environment | Operating temperature: -20 to 70°C
Storage temperature: -30 to 105 °C Humidity: relative humidity 5%–95% |
| Software support | (HTLock Management System
(LDRenting Apartment Management System) |
2. direction for use
2.1 Understanding Elevator Button Wiring Sequences
The floor-call buttons in elevators typically use a 4-wire system: two wires are indicator-light wires (usually accompanied by an LED symbol) and do not need to be connected to the controller; the remaining two wires are button-signal wires (usually accompanied by a switch symbol) and must be connected to the relays on the elevator control board.

Figure 2.1: Common floor-selection button layouts found on the market
2.2 Work Mode Description
Depending on whether manual floor selection is required after card reading, the elevator control system supports two wiring logic modes: standard mode and direct-access mode.
- Standard mode: After the card verification is successful, the user must manually press the button corresponding to the desired floor to activate the elevator.
- Direct-access mode: After the card verification is successfully completed, the elevator will directly reach the designated floor without the need to manually press any buttons. (Note: This feature is available only with single-floor access cards; multi-floor access cards still require manual floor selection.)
2.3 Overall wiring diagram

Figure 2.2 Schematic diagram of the overall wiring for the stairway controller (illustrating the wiring configuration in standard mode)
2.4 Wiring of the escalator control buttons
2.4.1 Normal Mode

Figure 2.3 Schematic diagram of wiring in normal mode
Wiring in normal mode (power-off operation):
Simply cut off either one of the two-core signal wires from the original floor-button wiring, then connect it respectively to the corresponding COM (common terminal) and NC (normally closed terminal) terminals on the controller to establish series control.
operational principle:
- Standby state: The relay releases; NC and COM are disconnected, the button signal circuit is interrupted, and manually pressing the button has no effect.
- Card-swipe validity: The relay engages, NC and COM become conductive, and the button signal circuit is restored; at this point, manually pressing the button will start the elevator.
2.4.2 Direct Access Mode

Figure 2.4 Schematic diagram of the wiring arrangement for the direct connection mode
Direct-mode wiring (power-off operation):
Building upon the wiring configuration used in normal mode, an additional wire is added to connect to the controller’s NO (normally open) terminal. Specifically, the signal wire from the original button that was not cut off is connected in parallel to the NO terminal corresponding to the respective floor.
operational principle:
- Standby state: The relay de-energizes; the NC and COM contacts open, and the NO and COM contacts also open. The button circuit is physically interrupted, and manual operation is ineffective.
- Card reading is valid (floor-specific access permission, e.g., for guest cards): The relay momentarily engages, causing the NO and COM contacts to briefly close. This simulates a single button press, and the elevator automatically moves to the target floor without requiring manual intervention.
- Card reading is valid (multi-floor access permissions, e.g., master card): the relay remains engaged, and NC and COM remain continuously conductive; only the button-access permission is restored. The user must manually select the floor (i.e., the direct-access function is not enabled).
3. Escalator control audio-visual alert
The audible and visual prompts for the escalator control are shown in Table 2.1.
Table 2.1: Escalator Control Audio-Visual Indicators
| function | Escalator control audio-visual alert | |
| Functional Status Indicator Class | ||
| Routine functional indicators | Pre-conception status not assessed | For the ladder controller that has not undergone production testing, the blue light flashes continuously once per second: it stays on for 200 ms and then turns off for 800 ms… The flashing continues until the production test is executed; only then does the flashing stop. |
| initialise | After briefly pressing the button, the blue light will remain on continuously for 10 seconds. | |
| After the button is held down for 1 second, the red light will remain continuously illuminated. | ||
| When the button is held down for 10 seconds, the buzzer emits two short beeps, and the red light flashes rapidly at a rate of five times per second: 50 ms on – 150 ms off – 50 ms on – 150 ms off… | ||
| Hold the button for 10–30 seconds to release it; the buzzer will emit one long beep, indicating that initialization was successful. | ||
| If the button is held down for more than 30 seconds without being released, the buzzer will emit three short beeps at the 30-second mark, the blue light will illuminate, and initialization will fail. | ||
| Bluetooth pairing in the initialized state | When entering pairing mode, the buzzer will emit three long beeps to initiate the pairing process. | |
| During the pairing process, the red and blue lights flash alternately (800 ms red – 800 ms blue – 800 ms red – 800 ms blue…); the Bluetooth pairing status will remain active for 1 minute. | ||
| Operation successful | The buzzer emits a long, continuous tone. | |
| Operation failed | During the firmware upgrade, the blue light flashes continuously once per second: it is on for 50 ms and off for 950 ms…. | |
| The buzzer emits three short beeps. | ||
| Synchronizing data | During the synchronous device recording period, the blue light flashes continuously once per second: it stays on for 50 ms and turns off for 950 ms…. | |
| Firmware upgrade in progress | During the firmware upgrade, the blue light flashes continuously once per second: it is on for 50 ms and off for 950 ms…. | |
| Alert category | ||
| Card swipe failure message | The card was replaced. | The red light remains on for 1 second and then turns off; the buzzer emits two short beeps. |
| The card is no longer valid. | The red light remains on for 1 second and then turns off; the buzzer emits three short beeps. | |
| The card has been disabled. | The red light turns on for 1 second and then turns off; the buzzer emits four short beeps. | |
| Unauthorized key | Indicate “Operation Failed.” | |
| Power-on self-test fault message | Power-on self-test | During the self-test period, the red light flashes rapidly three times per second: it turns on for 50 ms, then turns off for 50 ms, then turns on for 50 ms, then turns off for 50 ms, then turns on for 50 ms, and finally turns off for 750 ms… |
| Power-on self-test completed successfully. | All button lights will illuminate for 2 seconds;
Shangdian Music; |
|
| Abnormality in the card verification circuit | One short beep; the signal is transmitted within 2 seconds (detection duration: 1 second). | |
| Set the button self-test anomaly flag | Three short beeps, played within 2 seconds (detection duration: 1 second). | |
| Abnormal card reading communication | Four short tones, played within 2 seconds (detection duration: 1 second). | |
4. Structural Dimensioning Diagram
The structure of the EVC01E-MB40W0-16-ZD elevator floor controller is shown in Figure 3.1.

Figure 4.1: Structural dimensions diagram of the EVC01E-MB40W0-16-ZD elevator floor controller
The structure of the EVC01E-MB40W0-16-ZD read head is shown in Figure 3.2.

Figure 4.2: Schematic diagram of the structural dimensions of the EVC01E-MB40W0-16-ZD read head