EVC03E 16th QR CARD Elevator control panel

Original price was: $408.00.Current price is: $310.00.

EVC03E-MBQ00W0-16-ZD  Door Control Installation Instruction Manual Click to Download catalogue Revised Version 2 2 Product Overview 4 4 1.1 1.1 Overview 4 4 1.2 1.2 Product Image 4 4 1.3 1.3 Functional Features 4 4 1.4 1.4 Functional Overview 5 5 Instructions for Use 6 6 2.1 2.1 Understanding the Wiring Sequence of Elevator Buttons 6 6 2.2 2.2 Description of Operating Modes 6 6 2.3 2.3 Overall Wiring Diagram 7 7 2.4 2.4 Wiring of the elevator control buttons 7 7 2.4.1 2.4.1 Standard Mode 7 7 2.4.2 2.4.2 Direct Mode 9 9 Escalator control audio-visual prompt 10 10…

Description

EVC03E-MBQ00W0-16-ZD  Door Control Installation Instruction Manual Click to Download

catalogue

Revised Version 2 2

  1. Product Overview 4 4

1.1 1.1 Overview 4 4

1.2 1.2 Product Image 4 4

1.3 1.3 Functional Features 4 4

1.4 1.4 Functional Overview 5 5

  1. Instructions for Use 6 6

2.1 2.1 Understanding the Wiring Sequence of Elevator Buttons 6 6

2.2 2.2 Description of Operating Modes 6 6

2.3 2.3 Overall Wiring Diagram 7 7

2.4 2.4 Wiring of the elevator control buttons 7 7

2.4.1 2.4.1 Standard Mode 7 7

2.4.2 2.4.2 Direct Mode 9 9

  1. Escalator control audio-visual prompt 10 10
  2. Structural Dimensional Drawing 11 11

 

1. Product Overview

1.1 summary

The EVC03E-MBQ00W0-16-ZD is an intelligent elevator floor controller that supports control via cards, Bluetooth, and QR codes. The single board provides 16 output interfaces (up to four boards can be cascaded, enabling coverage of 64 floors), and it supports flexible configuration of normally open/normally closed signals. The product employs an advanced integrated design and represents a new-generation elevator access-control device, offering advantages such as stable performance, efficient communication, high capacity, and strong compatibility.

1.2 Product image

1.3 functional characteristics

  • a.Supports three methods of elevator access verification: card, Bluetooth, and QR code scanning.
  • b.The time-based access control feature is supported; users whose access period has expired cannot use the service.
  • c.It supports Bluetooth Quick Connect functionality, enabling contactless elevator access using a smartphone.
  • d.Supports OTA updates

1.4 function Introduction

As shown in Table 1.1, this section provides an overview of the functions of the EVC03E-MBQ00W0-16-ZD elevator floor controller.

Table 1.1: Features of the EVC03E-MBQ00W0-16-ZD Elevator Floor Controller

function parameter
type of use Mifare card (MEVC) & Bluetooth & QR code scanning
Card reading distance 10~50mm
import not have
output 16 normally closed contacts; in direct-mode operation, there are an additional 16 normally open contacts.
power suppl 12V DC
current consumption 1000mA
environment Operating temperature: -20 to 70°C

Storage temperature: -30 to 105 °C

Humidity: relative humidity 5%–95%

Software Support (The HTLock Management System (Huixiang Apartment System)

 

2. direction for use

2.1 Understanding the wiring sequence of elevator buttons

The floor-call buttons in elevators typically use a 4-wire system: two wires are indicator-light wires (usually accompanied by an LED symbol) and do not need to be connected to the controller; the remaining two wires are button-signal wires (usually accompanied by a switch symbol) and must be connected to the relays on the elevator control board.

Figure 2.1: Common floor-selection button layouts found on the market

2.2 Work Mode Description

Depending on whether manual floor selection is required after card reading, the elevator control system supports two wiring logic modes: standard mode and direct-access mode.

  1. Standard mode: After the card verification is successful, the user must manually press the button corresponding to the desired floor to activate the elevator.
  2. Direct-access mode: After the card verification is successfully completed, the elevator will directly reach the designated floor without the need to manually press any buttons. (Note: This feature is available only with single-floor access cards; multi-floor access cards still require manual floor selection.)

2.3 Overall wiring diagram

Figure 2.2 Schematic diagram of the overall wiring for the stairway controller (illustrating the wiring configuration in standard mode)

2.4 Wiring of the escalator control buttons

2.4.1 Normal Mode

Figure 2.3 Schematic diagram of wiring in normal mode

Wiring in normal mode (power-off operation):

Simply cut off either one of the two-core signal wires from the original floor-button wiring, then connect it respectively to the corresponding COM (common terminal) and NC (normally closed terminal) terminals on the controller to establish series control.

operational principle:

  • Standby state: The relay releases; NC and COM are disconnected, the button signal circuit is interrupted, and manually pressing the button has no effect.
  • Card-swipe validity: The relay engages, NC and COM become conductive, and the button signal circuit is restored; at this point, manually pressing the button will start the elevator.

2.4.2 Direct Mode

Figure 2.4 Schematic diagram of the wiring arrangement for the direct connection mode

Direct-mode wiring (power-off operation):

Building upon the wiring configuration used in normal mode, an additional wire is added to connect to the controller’s NO (normally open) terminal. Specifically, the signal wire from the original button that was not cut off is connected in parallel to the NO terminal corresponding to the respective floor.

operational principle:

  • Standby state: The relay de-energizes; the NC and COM contacts open, and the NO and COM contacts also open. The button circuit is physically interrupted, and manual operation is ineffective.
  • Card reading is valid (floor-specific access permission, e.g., guest card): The relay momentarily activates, and the NO and COM contacts briefly close, simulating the action of pressing a button. The elevator then automatically travels to the target floor without requiring human intervention.
  • Card reading is valid (multi-floor access permissions, e.g., master card): the relay remains engaged, and NC and COM remain continuously conductive; only the button-access permission is restored. The user must manually select the floor (i.e., the direct-access function is not enabled).

3. Audible and visual prompts for escalator control

The audible and visual prompts for the escalator control are shown in Table 3.1.

Table 3.1: Escalator control audio-visual prompts

function Escalator control audio-visual alert
Functional Status Indicator Class
Routine functional indicators Pre-conception status Silent light indication
initialise When the button is held down for 10 seconds, the buzzer will emit two short beeps.
After the button is held down for 1 second, the red light will remain continuously illuminated.
Hold the button for 10–30 seconds to release it; the buzzer will emit one long beep, indicating that initialization was successful.
Hold the button for 10–30 seconds to release it; the buzzer will emit one long beep, indicating that initialization was successful.
If the button is held down for more than 30 seconds without being released, the buzzer will emit three short beeps at the 30-second mark, the blue light will illuminate, and initialization will fail.
Bluetooth pairing in the initialized state When entering pairing mode, the buzzer will emit three long beeps to initiate the pairing process.
During the pairing process, the blue light flashes in the pattern: 1 second on – 1 second off – 1 second on – 1 second off… The Bluetooth pairing status will remain visible for 1 minute.
Operation successful The buzzer emits a long, continuous tone.
Operation failed The buzzer emits three short beeps.
Synchronizing data Silent light indicator.
Firmware upgrade in progress Silent light indication
Alert category
Card swipe failure message The card was replaced. The buzzer emits two short beeps;
The card is no longer valid. The buzzer emits three short beeps;
The card has been disabled. The buzzer emits four short beeps;
Unauthorized key Indicate “Operation Failed.”
QR code scanning failure message The QR code is no longer valid. One short beep from the buzzer;
Invalid QR code One short beep from the buzzer;
Power-on self-test fault message Power-on self-test Shangdian Music;
Power-on self-test completed successfully. All button indicators will illuminate for 2 seconds;

Shangdian Music;

Abnormality in the card verification circuit One short beep; the signal is transmitted within 2 seconds (detection duration: 1 second).
Initialization button self-test anomaly Three short beeps, played within 2 seconds (detection duration: 1 second).
Card reading communication is common. Four short tones, played within 2 seconds (detection duration: 1 second).
The QR code scanning module is commonly used. No lighting; no music when powered on.

4. Structural Dimensioning Drawing

The structure of the EVC03E-MBQ00W0-16-ZD elevator floor controller is shown in Figure 4.1.

Figure 4.1: Structural dimensions diagram of the EVC03E-MBQ00W0-16-ZD elevator floor controller

The structure of the EVC03E-MBQ00W0-16-ZD reading head is shown in Figure 4.2.

Figure 4.2: Schematic diagram of the structural dimensions of the EVC03E-MBQ00W0-16-ZD reader head

 

 

Additional information